Services
Data Center and Facilities
Air
Flow Optimization
Understanding the effects of a high speed invisibly
moving fluid in both open an plenum spaces and when myriad high speed
fans cause continuous turbulence requires real time monitoring. Let us
assist you in monitoring,
optimizing
the use and minimizing the costs of cool air. Our tools provide real time
monitoring and modeling and provide the metrics for making informed decisions and formulate strategies.
We provide both Rack Cooling Index (RCI®) and Return Temperature Index
(RTI®) support services.
Commissioning
We provide data center commissioning support services
and documents or can coordinate with the client to provide a third party
commissioning agent. We coordinate the critical monitoring during the
process, report evaluation from equipment vendors and load documentation
during commissioning. We follow NETA testing standards 5 step commissioning
process. These steps include
Level 1 - Submittal review and factory testing
Level 2 - Site inspection and verification to submittal
Level
3 - Installation inspections and verifications to design drawings
Level 4 - Component testing to design loads
Level 5- System integration tests at full design loads
Energy Efficiency & Capacity Planning
Data
center decision making is a high-stakes business. Engage us as your data
center specialist resource to develop, validate and support your program.
We can assist in developing a comprehensive, short and long range data
center strategies that aligns with governance guidelines and business
mandates.
Environmental
& Energy Monitoring
We
are authroized resellers and systems integration of the SynapSense wireless
sensor network (WSN).
This versatile, flexible system can gather
temperature, humidity, differential air pressure, volumetric water flow,
water temperature, leak detection, "open door" and power monitoring
sample readings and provide management reports to maximize the effectiveness
and minimize the OPEX of your data center, technology rooms. labs and
technology closets. This system can provide real time "Active Control™"
to your CRAHS and CRACS by continuously aligning cooling capacity with
changes in IT load. This unique approach to control can optimzie cooling
capacity and saves 20-35% of cooling costs.
We also provide CFD modeling support for "what if" scenarios
to potential changes in your data center.
Project
Management
Our
seasoned Project Management professionals provides more than 30 years
of experience in Project Management in the technology sector, ranging
from Medium and High Density Data Centers and
Network Rooms to Class 1 Clean Room environments.
We
provide regular meeting minutes, regular budget updates, schedule updates
and photo updates to the client to track the progress for an on time/on
budget delivery of the project. We recognize not all on any team have
the same technology software and we use the most recent commercial tools
to provide information to all on the team during the project. We encourage
the central location of drawings, submittals, RFI’s, and Cx documents
for team review.
Risk
& Site Assessments
We
provide data center risk and site assessments for existing data centers.
Scope of work includes the investigation, review, documentation and analysis
of current operational conditions of your data center. We identify risks
that could endanger your company's or agency's ability to function and
cause injury to staff, equipment and infrastructure. We will help you
establish a baseline for ongoing pro-active risk management practices.
Scope
of work includes
Architectural - Includes review of design drawing and modifications,
verify compliance to current codes,
determine solutions for any out-olf-compliance items and
review Hazmat compliance.
Electrical - Includes review of design drawings and modifications,
determine design capacity vs. installed
capacity
vs. expandable usable capacity. Verify IT loads on electrical equipment,
observe power
monitoring,
power quality monitoring. Document PDU;s, UPS's, SWBD's, Generators, Parallel
SWBD,
ATS;s, coordination study and updates, tranfer tests, and maintenance
of above.
Mechanical - Includes review and understanding of current DC mechanical
uses, trend for
expansion/replacement, modifications to expand deisgn capacity.
Verify loads on mechanical equipment, observer monitoring,
review back-up and
water storage needs.
Fire Systems
EPO Systems
Leak Detection Systems
Monitoring and Control Systems
Security Systems
Physical Network Installations
|